Kansas City, MO

Stability Testing Kansas City, MO

Stability Testing Kansas City, MO. Medical and pharmaceutical advancement cannot exist without stability testing, and stability testing is not possible without precise, high-quality stability chambers for pharmaceutical use. Darwin Chambers has been the frontrunner in chambers for stability testing, FDA/ICH pharmaceutical storage, and a number of other uses in the medical and pharmaceutical industries in Kansas City, MO. When you need stability testing equipment you can trust or any type of environmental chamber that performs without fail, turn to Darwin Chambers.

Contact Darwin Chambers today to learn how we can work together to produce the stability testing chambers that are right for you. Request a quote for the right Kansas City, MO reach-in stability testing chamber for your application, design your fully customized walk-in stability testing chamber for you Kansas City, MO location, or speak to one of our knowledgeable associates about the perfect stability testing to meet your needs.

Kansas City, MO Stability Testing

Pharmaceutical stability testing is a type of testing used to establish how long a drug or product remains effective and safe for use at specific storage conditions. The process of stability testing is achieved by keeping the material at defined conditions and measuring its properties periodically. This task would not be possible without access to reliable and accurate Kansas City, MO stability chambers. Darwin Chambers is your source for pharmaceutical stability chambers.

What To Look For from a Stability Testing Chamber?

Whether you work in pharmaceuticals, other medical devices, or any FDA-regulated products in Kansas City, MO, you must be able to perform stability testing. To perform stability testing in Kansas City, MO that meets or exceeds the industry's strict industry standards and regulations, your operation needs qualified personnel in addition to performance stability chambers and stability rooms. A team of the most brilliant minds alive cannot be effective without facilities with quality stability chambers that exceed the stringent stability testing standards laid forth by the FDA and ICH.

Purchasing stability chambers and other equipment for your Kansas City, MO operation to fulfill your stability testing needs is no small investment. Your operation and ability to conduct Kansas City, MO stability testing depend upon your stability chambers; you must choose a quality product that meets your precise needs. Darwin Chambers is the trusted leader in stability chamber production for your Kansas City, MO stability testing application, whether you need a compact bench-top reach-in stability chamber or a fully customized stability chamber room.

When searching for the right stability chambers for your Kansas City, MO stability testing work, it is important to consider your options on the following criteria:

  1. Control - You cannot use a chamber for stability testing in the US unless it meets ICH requirements. Typically that means control of ± 2°C and ± 5% RH. Darwin Chambers' products far exceed these specifications, with standard controls with a range of ±0.2°C and ±0.3% RH. Our line of stability chambers, refrigerators, and freezers are fitted with precise and simple controls or optional virtual touchscreen technology.
  2. Conditioning - A chamber must ensure uniform distribution of temperature and humidity throughout its inside and should be designed to recover from open doors or loss of power. Darwin Chambers' stability chambers use ultrasonic humidity and thermoelectric cooling technologies, of hot spots. In addition, our stability chambers are cooled using a system of multiple, independent cooling units to keep the inside as steady as possible for your Kansas City, MO stability testing work.
  3. Construction - You deserve a quality constructed stability chamber that has the ability to serve you reliably for years to come. Our stability testing chambers are assembled with the best materials and designs, including stainless steel exteriors, positive seal self-closing doors, and foamed-in-place high-density insulation. The majority of the components on our chambers can be serviced quickly and simply.

Kansas City, MO Stability Testing Our Chambers Accommodate

Stability testing in Kansas City, MO can and should be done on many different substances and should measure a variety of characteristics based on a range of specific environmental conditions. Darwin Chambers engineers, manufactures, and installs stability chambers and other environmental chambers that are perfect for your Kansas City, MO stability testing needs. Choose from our line of stability chambers with a number of standard and customized reach-in and walk-in chambers.

You can count on Darwin Chambers' stability chambers to allow you to carry out stability testing in Kansas City, MO to measure:

  • Physical Characteristics
    • Appearance
    • Melting point
    • Moisture content
    • Clarity and color of the solution
    • pH
    • Dissolution
    • Disintegration
    • Viscosity
    • Crystal modification
    • Particle size
  • Chemical Characteristics
    • Assay
    • Degradation
    • Related substances
    • Residual solvents
    • Radioactive decay
    • Packaging and interaction
  • Microbial
    • Sterility
    • The efficacy of antimicrobial preservatives
    • Antioxidants
    • Microorganism growth
    • Environmental control
  • Therapeutic Characteristics
  • Toxicological Characteristics
  • Biocompatibility

We offer environmental chambers to meet your every need. Learn more about some of our popular services and products below.

Stability Testing: ICH Guidelines

We have made sure that our stability chambers are engineered and built to provide exact control of conditionsso that you can conduct Kansas City, MO stability testing that is accepted by ICH stability testing guidance.

Our stability chambers allow you to do:

  1. Real time/long term stability testing - testing is usually done every three months during the first year, every six months during the second year, and once a year after that for the duration of the study
  2. Intermediate stability testing - for a 12 month study, it is recommended that testing is conducted a total of four times including the initial and final tests
  3. Accelerated stability testing - for a six month study, it is recommended that tests are done a total of three times at regular intervals, including the initial and final tests

Kansas City, MO Stability Testing Chambers: Darwin Chambers

Darwin Chambers is the leader in Kansas City, MO stability testing products. Get the reach-in or walk-in chambers you need to perform the stability testing your work requires. WIth superior accuracy, control, customability, and efficient systems, our stability chambers make stability testing possible in Kansas City, MO. Get a look at which products are right for you or talk to an expert about your Kansas City, MO stability testing chamber needs now at 877-783-6774 or reach us online.