Jacksonville, FL

Environmental Chambers Jacksonville, FL - Repair, Installation, and Testing

Darwin Chambers is the leading provider of Environmental Chambers in Jacksonville. Environmental Chambers must operate at peak capacity, and Darwin Chambers' engineers can provide validation, testing, maintenance or installation for any environmental chamber needed in Jacksonville. To learn more about our methods and capabilities, contact our Environmental Chamber Engineers in Jacksonville at 877-783-6774.

Environmental Chamber Maintenance Jacksonville, FL

Darwin Chambers offers a thorough preventive maintenance package to help protect your investment and provide peace of mind. A listing of available services follows. Please note, not all services may be applicable to a specific chamber model or type.

Desiccant Dryer Check-Out

  • Verify no fault indications exist on front panel and that no lights are burned out
  • Check the react outlet air temperature
  • Verify proper operation of damper actuators
  • Verify proper rotation of drive motor
  • Verify process air blower is operational
  • Inspect desiccant wheel for dirt or debris
  • Inspect desiccant wheel gaskets for wear
  • Clean the process air filter
  • Check for abnormal noise or vibration
Control Panel Check-Out

  • Verify that there are no loose wires
  • Measure voltage/amps for all motors
  • Measure voltage/amps for all heaters
  • Verify all alarms function properly
  • Verify window heaters are operational
  • Verify door heaters are operational
  • Verify chamber ceiling lights and light switch are operational
Humidifier Check-Out

  • Verify there is not any mineral deposits
  • Measure voltage/amps of each humidifier
  • Remove any scale build-up inside the humidifier
  • Check water supply pressure
  • Check for any leaks or signs of corrosion
Condensing Unit/Plenum Check-Out

  • Check refrigerant charge
  • Check compressor oil level
  • Check system operating pressures
  • Check CPR pressure setting
  • Check capillary tubes do not rub
  • Verify no oil traces are present
  • Verify no leaks are present
  • Clean the condenser coils if needed
  • Measure compressor voltage/amps
  • Measure crankcase heater voltage/amps
  • Measure condenser fan voltage/amps
  • Check for any abnormal noise or vibration

Download Maintenance Brochure

Environmental Chamber Qualification Jacksonville, FL

Typically entailing a three-part process, our Full Qualification services are listed below.

The Installation Qualification (IQ) is utilized for providing documented verification that all key aspects of the design, procurement, and installation adhere to the design intention.

The Operational Qualification (OQ) is utilized for providing documented verification that the systems and subsystems perform as intended at all anticipated operating ranges (normally performed with an unloaded chamber).

The Performance Qualification (PQ) is utilized for providing documented verification that the process does what it is intended to do, in the correct and anticipated manner (normally performed with either a simulated or actual product load in the chamber).

Download Qualification Brochure

Environmental Chamber Testing Jacksonville, FL - Environmental Chamber Calibration Jacksonville

Alongside our installation and repair services, we also provide environmental chamber testing and calibration. Environmental Chambers are required to operate at specified levels to ensure that products and operations are protected.

Correct Calibrations hold a critical role in your industry, that's why our engineers use extremely precise calibration standards. These standards set high calibration requirements (NIST National Institute of Standards and Technology), in order to meet or exceed manufacturer’s specifications.

We can also offer programs that are tailored to fit your needs, such as single point or loop calibrations and verifications. Our procedure provides a 3-point “as-found” calibration verification. The “as-found” readings are documented and verified to be within the manufacturer’s tolerance, if found within the tolerances the device is then returned to service. If any instrument exceeds the tolerance, we will promptly notify you, so that you may take the necessary steps to document the event.

Additionally, if the “as-found” readings are not within the manufacturer’s tolerance, the instrument is then calibrated using the manufacturer’s calibration procedure. After completing the calibration, the instrument’s “as-left” readings are documented using the same three points from the calibration verification to ensure the instrument is reading within the manufacturer’s tolerance.

Download Testing Brochure

Environmental Chambers Installation, Calibration and Maintenance Jacksonville, FL

Darwin Chambers Custom Walk-In-Rooms offer applications and uses that satisfy the requirement of modern industries in Jacksonville. All of our Environment Chambers are customizable and can be made to any specifications that a modern industry may need. To inquire about other controlled environment room solutions that we offer to Jacksonville businesses, please contact Darwin Chambers at your earliest convenience.

  • Quick and Easy Setup

    Entire cooling systems can be installed and replaced, quickly, with simple tools - no refrigeration tools or certified technicians necessary.

  • Elegant Designs

    We have the capability to offer the best operational fit for your specific requirements—while typically providing systems that are the most efficient, sustainable, and competitively priced, as well.

  • Customized Solutions

    Flexibility and an expert engineering and design team, to provide innovative and highly customized solutions, in addition to our standard product.

  • 24/7 Technical Support

    Free 24/7 technical support via phone or e-mail, throughout the lifetime of your Darwin Chambers product.

  • Temperature & Humidity Control

    Exceptional temperature and humidity control due to proportional microprocessor control.

  • Precision Fluid Temperature Control Unit

    A proprietary indirect cooling system for walk in's. It utilizes a combination of refrigeration technologies, propylene glycol/water heat exchange technologies, and the latest temperature control methods in order to out perform conventional refrigeration systems.

 *View Our Stability Room Pricing Special

FDA / ICH Stability Rooms

FDA / ICH Stability Rooms

Our stability chambers offer superior environment control for a variety of applications, and are proven to exceed ICH/FDA stability requirements.

Environmental Rooms

Environmental Rooms

Darwin Chambers Company designs, manufactures, installs, and services custom chambers of all types and sizes, for a wide array of applications.

Insect Rearing Rooms

Insect Rearing Rooms

We have over a decade of highly specialized experience in insect rearing working with researchers to address their needs for studies involving droso …

Cold Rooms

Cold Rooms

Our walk-in cold rooms offer reliable, efficient environmental controls for a variety of applications; including: GMP Storage and Cold Storage for S …

Freezers

Freezers

Darwin Chambers Company Freezer Rooms are designed for maximum reliability, efficiency, and stability.

Incubator / Warm Rooms

Incubator / Warm Rooms

Our walk-in incubators offer reliable, efficient environmental controls for a variety of applications.

Plant Growth Rooms

Plant Growth Rooms

Darwin Chambers Company provides Plant Growth Rooms that are engineered for maximum value, sustainability, and conformance with USDA-APHIS standards …

Material / Test Cure

Material / Test Cure

Our walk-in Materials Test and Cure Rooms offer reliable, efficient environmental controls for a variety of applications.

Archival Storage Rooms

Archival Storage Rooms

Darwin Chambers Company’s NFPA, GSA, and NARA Directive 1571-compliant Archival Storage Chambers are engineered to provide maximum value, efficien …

Altitude Test Rooms

Altitude Test Rooms

Darwin Chambers Company has teamed up with Colorado Altitude Training (CAT), located in Boulder Colorado, to offer a unique chamber for altitude sim …