Environmental Chambers Oakland, CA - Repair, Installation, and Testing Darwin Chambers is the leading provider of Environmental Chambers in Oakland. Our engineers have the capacity and training to certify, test, and maintain or repair a vast selection of environmental chambers. To learn more about our methods and capabilities, contact our Environmental Chamber Engineers in Oakland at 877-783-6774. Environmental Chamber Maintenance Oakland, CA Our preventative maintenance packages ensure that your environmental chamber in Oakland is fully operational at all times. Provided below is a list of services applicable to different chambers and applications. Desiccant Dryer Check-Out Verify no fault indications exist on front panel and that no lights are burned out Check the react outlet air temperature Verify proper operation of damper actuators Verify proper rotation of drive motor Verify process air blower is operational Inspect desiccant wheel for dirt or debris Inspect desiccant wheel gaskets for wear Clean the process air filter Check for abnormal noise or vibration Control Panel Check-Out Verify that there are no loose wires Measure voltage/amps for all motors Measure voltage/amps for all heaters Verify all alarms function properly Verify window heaters are operational Verify door heaters are operational Verify chamber ceiling lights and light switch are operational Humidifier Check-Out Verify there is not any mineral deposits Measure voltage/amps of each humidifier Remove any scale build-up inside the humidifier Check water supply pressure Check for any leaks or signs of corrosion Condensing Unit/Plenum Check-Out Check refrigerant charge Check compressor oil level Check system operating pressures Check CPR pressure setting Check capillary tubes do not rub Verify no oil traces are present Verify no leaks are present Clean the condenser coils if needed Measure compressor voltage/amps Measure crankcase heater voltage/amps Measure condenser fan voltage/amps Check for any abnormal noise or vibration Download Maintenance Brochure Environmental Chamber Qualification Oakland, CA Complete Qualification services are generally a three-part process. The Installation Qualification (IQ) provides documentation stating that the fundamental aspects of the chamber meet or exceed the design, procurement and installation needs. The Operational Qualification (OQ) provides further documentation that the chamber is operating as intended with its systems and subsystems, as well as all anticipated operating ranges. The Performance Qualification (PQ) provides documentation verifying that the environmental chamber works as it's intended to, and that it works in the correct manner. This is typically verified either with a simulation or when the chamber is actually in use. Download Qualification Brochure Environmental Chamber Testing Oakland, CA - Environmental Chamber Calibration Oakland Alongside our installation and repair services, we also provide environmental chamber testing and calibration. Environmental Chambers are required to operate at specified levels to ensure that products and operations are protected. Correct Calibrations hold a critical role in your industry, that's why our engineers use extremely precise calibration standards. These standards set high calibration requirements (NIST National Institute of Standards and Technology), in order to meet or exceed manufacturer’s specifications. We also offer tailored services such as loop calibrations or single point calibrations and verifications. Our procedure provides a 3-point “as-found” calibration verification. The “as-found” readings are documented and verified to be within the manufacturer’s tolerance, if found within the tolerances the device is then returned to service. If any instrument exceeds the tolerance, we will promptly notify you, so that you may take the necessary steps to document the event. Additionally, if the “as-found” readings are not within the manufacturer’s tolerance, the instrument is then calibrated using the manufacturer’s calibration procedure. After completing the calibration, the instrument’s “as-left” readings are documented using the same three points from the calibration verification to ensure the instrument is reading within the manufacturer’s tolerance. Download Testing Brochure Environmental Chambers Installation, Calibration and Maintenance Oakland, CA Darwin Chambers has an exceptional offer of applications that are designed to satisfy the needs of industries in Oakland. All of our Environment Chambers can be customized to any specializations or specifications that may be needed. To inquire about other controlled environment room solutions that we offer to Oakland businesses, please contact Darwin Chambers at your earliest convenience. Quick and Easy Setup Entire cooling systems can be installed and replaced, quickly, with simple tools - no refrigeration tools or certified technicians necessary. Elegant Designs We have the capability to offer the best operational fit for your specific requirements—while typically providing systems that are the most efficient, sustainable, and competitively priced, as well. Customized Solutions Flexibility and an expert engineering and design team, to provide innovative and highly customized solutions, in addition to our standard product. 24/7 Technical Support Free 24/7 technical support via phone or e-mail, throughout the lifetime of your Darwin Chambers product. Temperature & Humidity Control Exceptional temperature and humidity control due to proportional microprocessor control. Precision Fluid Temperature Control Unit A proprietary indirect cooling system for walk in's. It utilizes a combination of refrigeration technologies, propylene glycol/water heat exchange technologies, and the latest temperature control methods in order to out perform conventional refrigeration systems. Bacteriological IncubatorIncubation ChambersReach-In Chamber ManufacturerLow Temperature Biochemical IncubatorICH Stability Storage *View Our Stability Room Pricing Special