Boston, MA

Cold Room Boston, MA - Repair, Installation, and Testing

Darwin Chambers is the leading provider of Cold Rooms in Boston. With years of proven and tested industry experience, Darwin Chambers' engineers can install, maintain, test, and repair a vast selection of cold room chambers to ensure that your operations are performing at peak capacity. To learn more about our methods and capabilities, contact our Cold Room Engineers in Boston at 877-783-6774.

Cold Room Maintenance Boston, MA

Darwin Chambers offers a thorough preventive maintenance package to help protect your investment and provide peace of mind. Provided below is a list of services applicable to different chambers and applications.

Desiccant Dryer Check-Out

  • Verify no fault indications exist on front panel and that no lights are burned out
  • Check the react outlet air temperature
  • Verify proper operation of damper actuators
  • Verify proper rotation of drive motor
  • Verify process air blower is operational
  • Inspect desiccant wheel for dirt or debris
  • Inspect desiccant wheel gaskets for wear
  • Clean the process air filter
  • Check for abnormal noise or vibration
Control Panel Check-Out

  • Verify that there are no loose wires
  • Measure voltage/amps for all motors
  • Measure voltage/amps for all heaters
  • Verify all alarms function properly
  • Verify window heaters are operational
  • Verify door heaters are operational
  • Verify chamber ceiling lights and light switch are operational
Humidifier Check-Out

  • Verify there is not any mineral deposits
  • Measure voltage/amps of each humidifier
  • Remove any scale build-up inside the humidifier
  • Check water supply pressure
  • Check for any leaks or signs of corrosion
Condensing Unit/Plenum Check-Out

  • Check refrigerant charge
  • Check compressor oil level
  • Check system operating pressures
  • Check CPR pressure setting
  • Check capillary tubes do not rub
  • Verify no oil traces are present
  • Verify no leaks are present
  • Clean the condenser coils if needed
  • Measure compressor voltage/amps
  • Measure crankcase heater voltage/amps
  • Measure condenser fan voltage/amps
  • Check for any abnormal noise or vibration

Download Maintenance Brochure

Cold Room Qualification Boston, MA

Typically entailing a three-part process, our Full Qualification services are listed below.

The Installation Qualification (IQ) provides documentation stating that the fundamental aspects of the chamber meet or exceed the design, procurement and installation needs.

The Operational Qualification (OQ) provides further documentation that the chamber is operating as intended with its systems and subsystems, as well as all anticipated operating ranges.

The Performance Qualification (PQ) provides documentation verifying that the cold room chamber works as it's intended to, and that it works in the correct manner. This is typically verified either with a simulation or when the chamber is actually in use.

Download Qualification Brochure

Cold Room Testing Boston, MA - Cold Room Calibration Boston

In addition to our cold room installation and repair services, we also provide cold room testing and calibration. Cold Room Chambers are required to operate at specified levels to ensure that products and operations are protected.

Calibrations are critical to ensuring the accuracy of products and investments in your industry. The use of these standards will ensure that your instruments are calibrated to a standard (NIST National Institute of Standards and Technology), in order to meet or exceed manufacturer’s specifications.

We can also offer programs that are tailored to fit your needs, such as single point or loop calibrations and verifications. Our procedure provides a 3-point “as-found” calibration verification. The “as-found” readings are documented and verified to be within the manufacturer’s tolerance, if found within the tolerances the device is then returned to service. If any instrument exceeds the tolerance, we will promptly notify you, so that you may take the necessary steps to document the event.

Additionally, if the “as-found” readings are not within the manufacturer’s tolerance, the instrument is then calibrated using the manufacturer’s calibration procedure. After completing the calibration, the instrument’s “as-left” readings are documented using the same three points from the calibration verification to ensure the instrument is reading within the manufacturer’s tolerance.

Download Testing Brochure

Cold Room Installation, Calibration and Maintenance Boston, MA

Darwin Chambers Custom Walk-In-Rooms offer applications and uses that satisfy the requirement of modern industries in Boston. All of our Cold Room Chambers can be designed to meet the needs of any build or application. To inquire about other controlled environment room solutions that we offer to Boston businesses, please contact Darwin Chambers at your earliest convenience.

  • Quick and Easy Setup

    Entire cooling systems can be installed and replaced, quickly, with simple tools - no refrigeration tools or certified technicians necessary.

  • Elegant Designs

    We have the capability to offer the best operational fit for your specific requirements—while typically providing systems that are the most efficient, sustainable, and competitively priced, as well.

  • Customized Solutions

    Flexibility and an expert engineering and design team, to provide innovative and highly customized solutions, in addition to our standard product.

  • 24/7 Technical Support

    Free 24/7 technical support via phone or e-mail, throughout the lifetime of your Darwin Chambers product.

  • Temperature & Humidity Control

    Exceptional temperature and humidity control due to proportional microprocessor control.

  • Precision Fluid Temperature Control Unit

    A proprietary indirect cooling system for walk in's. It utilizes a combination of refrigeration technologies, propylene glycol/water heat exchange technologies, and the latest temperature control methods in order to out perform conventional refrigeration systems.

Why Choose Darwin Chambers?

  1. Over 20 years of experience in providing rooms of varied complexity, highly efficient, eco-friendly technologies and systems.
  2. A dedicated, internal Service Department, providing full calibration and validation services.
  3. An industry-leading seven-year warranty on our thermoelectric system for reach in's.
  4. Entire cooling systems can be installed and replaced, quickly, with simple tools - no refrigeration tools or certified technicians necessary.
  5. Exceptional temperature and humidity control due to proportional microprocessor control.
  6. A Precision Fluid Temperature Control Unit (PFTCU) is a proprietary indirect cooling system for walk in's. It utilizes a combination of refrigeration technologies, propylene glycol/water heat exchange technologies, and the latest temperature control methods in order to out perform conventional refrigeration systems.
  7. Available extended warranty and preventive maintenance agreements, to most locations within the contiguous USA.
  8. Free 24/7 technical support via phone or e-mail, throughout the lifetime of your Darwin Chambers product.
  9. Skilled, knowledgeable staff, to ensure that we ask the right questions, and have a complete understanding of our customer’s needs as well as all other regulations, requirements, and project considerations and constraints.
  10. Flexibility and an expert engineering/design team, to provide innovative and highly customized solutions, in addition to our standard product.
  11. “Elegant” design. We have the capability to offer the best operational fit for your specific requirements—while typically providing systems that are the most efficient, sustainable, and competitively priced, as well.

Other Locations We Service