New York, NY

Stability Testing New York, NY

Stability Testing New York, NY. Stability testing is a vital part of the pharmaceutical and medical development process and is not possible without reliable, high-quality stability chambers for pharmaceutical use. As Darwin Chambers, we are an established frontrunner in chambers for New York, NY stability testing, FDA/ICH pharmaceutical storage, and many other uses in pharmaceuticals, medical device storage, and many other industries. Trust none other than Darwin Chambers to provide you with top-of-the-line environmental chambers and stability testing equipment you can rely upon.

Contact Darwin Chambers today to get a quote or discuss your stability testing needs with an expert. Request a quote for the right New York, NY stability chamber model for your application, select your fully customized New York, NY walk-in stability testing chamber, or speak to one of our knowledgeable associates about the right stability testing products for you.

New York, NY Stability Testing

In the pharmaceutical industry, stability testing is a type of testing used to establish how long a drug or product can be safely and effective used at at what specific storage conditions. Stability testing is achieved by keeping the material at specified conditions and measuring its properties periodically. In order to achieve this vital task, researchers and manufacturers of pharmaceuticals and other medical products must have access to dependable and accurate New York, NY stability chambers. Darwin Chambers is your source for pharmaceutical stability chambers.

What To Look For from a Stability Testing Chamber?

When you work with pharmaceuticals, other medical devices, or any FDA-regulated products, you must be able to perform New York, NY stability testing. To perform stability testing in New York, NY that meets or exceeds the industry's strict industry standards and regulations, your organization needs qualified personnel in addition to performance stability chambers and stability rooms. Your team may have access to the best minds in your field, but that is irrelevant without access to highly accurate and powerful stability chambers that are designed especially for FDA and ICH stability testing.

Purchasing proper equipment like stability chambers for your operation to fulfill your New York, NY stability testing needs is no small investment. Your operation and ability to conduct New York, NY stability testing depend upon your stability chambers; you must select a quality product that meets your stringent needs. Whether you need a small bench-top model for supplemental stability testing or need a completely customized walk-in stability chamber for high-volume stability testing in New York, NY, Darwin Chambers has the right product for you.

Consider the following characteristics when selecting stability chambers for your New York, NY stability testing operations:

  1. Control - A chamber is useless to you for stability testing if its control of conditions does not adhere to ICH requirements. This is generally ± 2°C and ± 5% RH. Darwin Chambers' designs far exceed these specifications, with standard controls with a range of ±0.2°C and ±0.3% RH. Our line of stability chambers, refrigerators, and freezers are fitted with precise and simple controls or optional virtual touchscreen technology.
  2. Conditioning - A chamber must ensure consistent temperature and humidity conditions throughout the interior of the chamber and must have the capability to recover from open doors or loss of power. Darwin Chambers' stability chambers are regulated with ultrasonic humidity and thermoelectric cooling technologies, of hot spots. In addition, our stability chambers are cooled using a system of multiple, independent cooling units to keep the inside as steady as possible for your New York, NY stability testing application.
  3. Construction - You deserve a quality constructed stability chamber that is prepared to run reliably for years to come. Our chambers designed for stability testing are designed with stainless steel exteriors, self-closing doors, and foamed-in-place high-density insulation. Nearly all components on our chambers can be serviced quickly and simply.

New York, NY Stability Testing Our Chambers Accommodate

Stability testing in New York, NY can test the effects of various environmental conditions on a number of different characteristics of nearly any drug or substance. Our chambers are designed, engineered, constructed, installed, and tested to fulfill your New York, NY stability testing needs. Choose from our line of stability chambers with a number of standard and customized reach-in and walk-in chambers.

Darwin Chambers stability chambers will allow you to carry out stability testing in New York, NY to measure:

  • Physical Characteristics
    • Appearance
    • Melting point
    • Moisture content
    • Clarity and color of the solution
    • pH
    • Dissolution
    • Disintegration
    • Viscosity
    • Crystal modification
    • Particle size
  • Chemical Characteristics
    • Assay
    • Degradation
    • Related substances
    • Residual solvents
    • Radioactive decay
    • Packaging and interaction
  • Microbial
    • Sterility
    • The efficacy of antimicrobial preservatives
    • Antioxidants
    • Growth in microorganisms
    • Environmental control
  • Therapeutic Characteristics
  • Toxicological Characteristics
  • Biocompatibility

We environmental chambers to meet your every need. Learn more about some of our popular services and products below.

Stability Testing: ICH Guidelines

We have made sure that our stability chambers in New York, NY are designed and built to give you acute manipulation of conditionsso that you can conduct New York, NY stability testing you need that conforms to ICH stability testing guidance.

With our stability chambers, you can perform:

  1. Real time/long term stability testing - testing is usually done every three months during the first year, every six months during the second year, and once a year after that for the duration of the study
  2. Intermediate stability testing - for a 12 month study, it is recommended that testing is conducted a total of four times including the initial and final tests
  3. Accelerated stability testing - for a six month study, it is recommended that tests are done a total of three times at regular intervals, including the initial and final tests

New York, NY Stability Testing Chambers: Darwin Chambers

Darwin Chambers is the leader in New York, NY stability testing products. Get the reach-in or walk-in chambers you need to perform the stability testing your work requires. WIth superior accuracy, manipulation, customization, and powerful systems, our stability chambers make stability testing possible in New York, NY. Get a look at which products are right for you or talk to an experienced associate about your New York, NY stability testing chamber needs now at 877-783-6774 or reach us online.

Schema