Pre-engineered Cold Room Special
Pre-engineered cold storage for a defined load.
Bring refrigerated storage into your facility with a standardized 10 × 10 ft room from Darwin Chambers. The LAB-G1NN-10X10 Cold Room Special operates at 2–8 °C, with a defined configuration to simplify project planning.
Cold Room Special · LAB-G1NN-10X10
10 × 10 ft
Standard room footprint
2–8°C
Refrigerated storage range
±0.2°C
Control at sensor; not room uniformity
Cold storage. A shorter path to installation.
A pre-engineered configuration gives you a starting point for refrigerated storage without designing every room detail from scratch. We match the room to your product, load, access pattern and required conditions. Qualified cold rooms can also support refrigerated stability work when their performance fits the study.
Save around 30% and shorten lead times with a pre-engineered configuration. Standardized design reduces the work needed to get started; your quote sets out current pricing, availability and project delivery.
See the cold room. Plan the space.
See the shelving arrangement, access and door swing before preparing your space. The LAB-G1NN-10X10 drawing shows the special’s fixed 10 × 10 ft footprint.
Our team works through utility connections, equipment clearances and installation responsibilities with you before the room arrives.
Temperature and moisture need separate decisions.
Keep the temperature requirement and moisture requirement clear. Cooling changes relative humidity and dew point; the product and operating conditions determine whether added moisture control is needed.
Add moisture
Humidification supplies moisture when the application calls for it. It is not a default inclusion carried over from the stability-room configuration.
Remove moisture
Desiccant or refrigeration-based drying can manage moisture in cold-room configurations. The equipment supplied with this special is defined in the project quotation.
Load & access affect performance
Shelving, incoming product and door openings affect airflow and recovery. An open air path helps the room operate as intended.
Defined operating conditions
The special is specified for ambient conditions of 22.2 °C ±4.4 °C and dew point at or below 11.1 °C. Extended operation below 4 °C may require defrost tolerances.
One coordinated path to installation.
Darwin brings the room layout, freight, installation, commissioning and calibration into one project conversation. Your quotation defines inclusions and site responsibilities.
01
Fit the room to the site
Use the drawing to establish access, shelving, product movement and exterior equipment clearances.
02
Prepare for delivery
Our team coordinates utilities, final connections and access with you. Permits, hoisting and third-party work are identified before installation.
03
Bring it into service
Set the calibration, mapping and qualification scope for your application, with maintenance and monitoring selected for the room’s ongoing use.
Need a stability room instead?
The Cold Room Special above is for 2–8 °C refrigerated storage. For warmer controlled-humidity conditions, the separate Stability Room Special offers a different operating range and moisture-control system.
Cold storage
Cold Room Special · 10 × 10 ft
LAB-G1NN-10X10
2–8 °C refrigerated storage. Published control at the sensor is ±0.2 °C under the specified operating conditions. Moisture-control equipment and any active RH requirement are configuration-specific; the stability room’s 60–75% RH range does not apply by default.
Controlled-humidity stability
Stability Room Special · ICH-G1HD-10X10
25–40 °C; 60–75% RH. Ultrasonic humidification and a desiccant dryer provide moisture control. Published sensor/set-point control is ±0.2 °C and ±0.3% RH, with qualification scope matched to the study.
Cold-room planning questions.
Is this the same as the Stability Room Special?
No. The documented cold special operates at 2–8°C. The stability special is specified at 25–40°C and 60–75%RH. Confirm the supplied moisture-control hardware and all current specifications with Darwin.
Is ±0.2°C the uniformity everywhere in the room?
No. It is the published control at the sensor. Temperature distribution across the room, recovery and loaded performance need separate evidence and agreed acceptance criteria.
Can I use it for a regulated storage or stability program?
Review the product’s required conditions, the intended use and the qualification evidence with your quality team. A chamber label or temperature range does not itself establish GMP compliance or suitability for every biological or clinical material.
Cold-room plans & resources.
Get the drawing and product information needed to plan access, utilities and usable storage space.
Cold Room Special drawing
See the footprint, shelving and access arrangement for LAB-G1NN-10X10. The current project drawing governs final dimensions and utilities.
Need a different cold-room configuration?
Explore custom cold rooms when you need another layout or configuration. The general 0–10 °C family range is separate from this 2–8 °C special.
Need controlled-humidity stability conditions?
Explore the separate pre-engineered stability room for a 25–40 °C, 60–75% RH operating range.
Tell us what needs to stay cold.
Tell us what you store, the required conditions and your available space. We’ll help you determine how the Cold Room Special fits, or develop a custom configuration for your project.