Darwin Chambers Company 24 cubic foot laboratory incubator TE024

TE024 Laboratory Incubator

Contact Darwin Chambers                             Price List                                  Our Technologies                                   Employment

laboratory incubator 24 cft

TE024 Laboratory Incubator

Call for pricing 314-534-3111

 

CABINET CONSTRUCTION:

• 300 series stainless steel front grill, shroud and doors. Anodized quality aluminum exterior ends and back.

• Interior – INSF approved, white vinyl coated aluminum and 300 series stainless floor with coved corners.

• Barrel lock standard for each door. Locks keyed alike.

• Cabinet mounted on a welded, galvanized frame rail, painted for additional corrosion protection.

• Frame rail fitted with 4" diameter casters, (front casters include brakes).

DOORS:

• 300 series stainless steel exterior with white aluminum interior to match cabinet liner. Doors extend full width of cabinet shell. Door gaskets of one piece construction.

• Lifetime guaranteed adjustable torsion type closure system with aluminum block supports. The face of each door fitted with a 12" long recessed handle with sheet metal interlock. Handles are foamed-in-place to insure permanent attachment.

INSULATION:

• Entire cabinet structure and doors insulated using foamed-in-place CFC free polyurethane foam.

SHELVING:

• Adjustable vinyl coated wire shelves (3 per door). Shelves capable of supporting up to 250 lbs.

• Full height shelf support pilasters, with double oblong holes on 1/2" centers. Pilasters made of the same material as cabinet interior. Four (4) chrome plated, stainless steel shelf clips to be included for each shelf.

LIGHTING:

• Incandescent interior lighting. Light(s) activated by rocker switch mounted above door(s).

REFRIGERATION SYSTEM:

• Top mounted, thermoelectric cooling system.

• Peltier based technology is solid state, highly efficient, reliable.

• Semi-Redundant cooling capability.

• Cooling surfaces act as dehumidifying modules at 25°C/60%RH and 30°C/65%RH

ELECTRICAL CHARACTERISTICS:

• Unit completely pre-wired at factory, and ready for final connection to a 115/60/1 phase - 15 amp dedicated outlet. A cord and plug set to be included.

• A sole use circuit is required.

Specs 
Temperature Range20°C-60°C
Temperature Control+0.2°C
Temperature Uniformity+1.0°C
Ambient Temp. Tolerance17°C – 30°C
Control Sensitivity0.1°C
Control ReadoutActual and Set-Point Values
SensorNIST-Traceable Platinum RTD
ControllerMicroprocessor based PID
Calibration CapabilityYes, actual and set values
AlarmAudible and visible
Alarm TypeAbsolute Hi/Lo in 0.1°C increments
Remote MonitoringAvailable
Electrical Requirements115v, 60 Hz, 10 amps
Interior Cubic Feet24
Required Clearance1" all sides
Number of Shelves3
Cord Length9'
Crated Weight300 lbs
schematic drawing of TE024 laboratory incubator