Call for pricing 314-534-3111
CABINET CONSTRUCTION:
• Standard model (pictured at right) features powder-coated door, front, and sides. Interior has 304 stainless steel on door liner, top, bottom, back and sides.
RACKING:
•Racking (as shown in pictures on right) available to to stack units.
DOOR:
• Positive magnetic seal. Reversible.
INSULATION:
• Entire cabinet structure and doors insulated using 2" urethane foam.
SHELVING:
• 2 stainless steel shelves are standard.
• Full height shelf support pilasters, with double oblong holes on 1" centers. Pilasters made of stainless steel. Four (4) chrome plated, stainless steel shelf clips to be included for each shelf.
| Standard Specs | |
| Temperature Range | 2°C to 60°C, -5°to 60°C with optional defrost |
| Temperature Control | +0.2°C |
| Temperature Uniformity | +0.8°C |
| Ambient Temp. Recommendation | 21°+3°C |
| Control Sensitivity | 0.1°C |
| Control Readout | Actual and Set-Point Values |
| Sensor | NIST-Traceable Platinum RTD |
| Controller | Microprocessor based PID |
| Humidity Range | Ambient to 90%, as limited by a 40°C dewpoint |
| Humidity Range with active dehumidification | 2-90%, as limited by a dewpoint range of -15°C to 40°C |
| Control of Humidity at Sensor | +0.3% RH |
| Humidity Uniformity | +2.0% |
| Calibration Capability | Yes, actual and set values |
| Alarm | Audible and visible |
| Alarm Type | Deviation in 0.1°C or 0.1%RH |
| Remote Monitoring | Available |
| Electrical | 115v, 60 Hz, 5 RLA |
| Interior Cubic Feet | 9 net |
| Required Clearance | 1" all sides |
| Number of Shelves | 2 |
| Cord Length | 7' |
| Crated Weight | 400 lb |
REFRIGERATION SYSTEM:
• Unsurpassed temperature control through continuous refrigeration bypass system.
• Refrigeration system factory balanced using CFC free 134A refrigerant.
• Top mounted condensing unit.
• Factory pre-engineered capillary tube system with oversized condenser and evaporator to reduce product pull down time and to consistently maintain interior cabinet temperature (non-adjustable capillary tube system superior to problematic expansion valve).
• Evaporator - epoxy coated at the time of manufacture to eliminate the potential of corrosion.
HUMIDITY CONTROL:
• NIST traceable 0.8% Rotronic humidity sensor w/cert. • Solid state controlled, ultrasonic humidifier with ceramic/titanium disk for long life.
ELECTRICAL CHARACTERISTICS:
• Unit completely pre-wired at factory, and ready for final connection to a 115/60/1 phase - 15 amp dedicated (recommended) outlet. • A cord and plug set is included.
• A sole use circuit is recommended.
Popular options include lighting, timed lighting, chart recorder, and TraceLock electronic/audit capable locks.